AMS Neve 4081 ユーザーズマニュアル

ページ / 23
4081 User Manual
Issue 2
For this switch, it is On when in the up position.
> Remove the lid to the unit, and set the 1
st
 (left-most) switch on this
block to be ON, then set the switches on the rear of the unit to the
following:
Unit ID
Switch 1
Switch 2
Switch 3
9
Off
Off
Off
10
On
Off
Off
11
Off
On
Off
12
On
On
Off
13
Off
Off
On
14
On
Off
On
15
Off
On
On
16
On
On
On
If a unit's ID is changed, the power must be switched off and on again for
the remote control software to receive the new ID number.
If the unit IDs are set incorrectly, they will either fail to respond or
multiple units will respond to a single command.
Technical Earth
When switched on, internally connects zero volts to the unit chassis.
- 8 -
This block of switches may
be covered with a thin
protective film, which will
need to be carefully removed
before attempting to set the
switches.