Send Trap Interval (sec): The time interval between two successive traps
when the number of transmitted broadcasts/multicasts exceeds the
permitted threshold.
when the number of transmitted broadcasts/multicasts exceeds the
permitted threshold.
The range is from 0 to 65535 seconds. 0 is for disabling traps sending.
The default is 300 seconds.
Auto-Config Tab
The Auto-Config tab enables quick configuration of various modes by setting
predefined values for several parameters upon clicking the applicable button.
predefined values for several parameters upon clicking the applicable button.
Figure
3-16: Auto-Config Tab
♦ Set PtP Mode: Click to set the following parameters to support optimized
configuration for Point-to-Point operation:
Minimum Contention Window = 15
RTS Threshold = 2437
♦ Set PtMP Mode: Click to set the following parameters to support optimized
configuration for Point-to-Multi-Point operation with 2-5 RBs:
Minimum Contention Window = 63
RTS Threshold = 2437 in BU, 60 in RB