Adder Technology ADDERLINK X2 ユーザーズマニュアル

ページ / 31
17




Password setting
Password protection allows you restrict access to the system only to authorised 
personnel. A password first needs to be set and then, using the keyboard 
attached to the REMOTE module, a simple key sequence allows the system to be 
quickly and securely detached from its peripherals.
To set a password
1  Simultaneously, press the hotkeys (by default, 
 and 
) along with 
 
to enter configuration mode.
2  Press   followed by 
.
3  Now enter your new password, within the following constraints:
•  Passwords are NOT case sensitive,
•  Passwords may be any length from one character to a maximum of forty 
characters,
•  The following keys may NOT be used: 
, or 
 
4  When you have entered the password, press 
 to signal its completion.
5  Press 
 once more to exit configuration mode.
For full details about how to lock and unlock the system using your password, 
please see the ‘Locking and unlocking the system’ section in the ‘Installation and 
operation’ chapter.
Password override
This mode allows you to override the password that has been set at the REMOTE 
module and place it into configuration mode so that a new one may be set. This 
feature is particularly useful when passwords have been lost or forgotten.
To override the REMOTE password
1  Remove power from the REMOTE module. 
2  With power to the system and LOCAL module still applied, change LOCAL 
switch 1 to the ON position.
3  Re-apply power to the REMOTE module. The REMOTE module will go 
directly into configuration mode so that the old password can be cleared 
and a new one set. 
•  
To clear a password: (within configuration mode) Press   followed by 
 and followed by 
 again. 
•  You can now enter a new password using the procedure outlined 
in steps 2 to 5 of the ‘Password setting’ section, or press 
 to exit 
configuration mode.   
4  Return LOCAL switch 1 to its OFF position. 
Note: If switch 1 remains ON, then the REMOTE module will enter 