Desa HD-9140 ユーザーズマニュアル
-7-
595-5660-06
Finish Mounting
❒
Align the fixture base plate, gasket, and the
junction box holes. Secure with mounting
screws that fit your junction box.
junction box holes. Secure with mounting
screws that fit your junction box.
❒
If not installed on a weatherproof box or if an
adaptor plate was used, caulk between the
base plate and mounting surface with sili-
cone weather sealant.
adaptor plate was used, caulk between the
base plate and mounting surface with sili-
cone weather sealant.
To avoid water damage
and electrical shock, keep
lamp holders aimed below
horizontal.
and electrical shock, keep
lamp holders aimed below
horizontal.
Specifications
Range . . . . . . . . . . . . . . Up to 100 feet (30.5 m) with
Range Boost On; up to 70
feet (21 m) with Range Boost
Off. (Varies with surround-
ing temperature).
feet (21 m) with Range Boost
Off. (Varies with surround-
ing temperature).
Sensing Angle . . . . . . . Up to 270
°
Sensor Load Capacity . Up to 1000 Watts (8.3 amps)
Maximum, Incandescent
Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and
MANUAL OVERRIDE
Time Delay . . . . . . . . . . 1 , 5, 20 minutes
Sensitivity . . . . . . . . . . . Adjustable