STARLINE 
RF Amplifier Quick Start Guide 
 
ADU Pads and Levels 
A JXP pad is installed in the input line to the ADU location. This pad adjusts the ADU input 
level for the standard application of the amplifier. This pad may be changed depending on the 
operational output of the amplifier. 
In general, the following JXP pad values are recommended in the amplifier ADU circuit and are 
the standard values installed at the factory. 
Amplifier 
Pad 
Amplifier Output Level Range 
BLE*/* 
JXP-6 
+42 dBmV to +50 dBmV at 550 MHz 
MB*/* 
JXP-14 
+42 dBmV to +50 dBmV at 550 MHz 
BT*/* 
JXP-6 
+41 dBmV to +51 dBmV at 550 MHz 
MBE*/* 
JXP-0 or 
JXP-ZX jumper 
+31 dBmV to +38 dBmV (trunk) and +40 dBmV to 
+47 dBmV (bridger) at 550 MHz 
To determine the correct ADU pad value for other output levels: 
!  Increase the ADU pad by 1 dB for every 1 dBmV increase in output level. 
!  Decrease the ADU pad by 1 dB for every 1 dBmV decrease in output level. 
The levels for the MBE
*/* assume a bridger gain 9 dB higher than the trunk. 
Return Path Alignment 
The following subsections describe procedures required to obtain proper return path alignment. 
Before You Begin 
For proper return path alignment obtain: 
RF alignment levels and insertion points for all amplifiers 
RF reference output level of the headend optical receivers 
A full complement of JXP-
*B pads and SRE-*-* return equalizers 
A reverse signal generator that produces at least one signal within the return bandpass and 
has a variable output 
Return sweep or alignment equipment 
It is recommended that you: 
Do not use wire jumpers to bypass the SRE-
*-* location. 
Set up the return optical link before you perform the amplifier set up. 
Specify reverse alignment design levels for a single carrier. 
Consider sweep equipment as a single carrier and operate at design levels. 
Do not include injection point losses in reverse design levels. 
If JXP THERM devices (JXP-TH
*B) are specified for level control, they need to be installed in 
the JXP THERM pad facility.