11
• Insert rubber grommets in all drilled holes to protect cables.
• Create permanent driplines (low points) on all cable routes before cables enter   roof holes, 
to help prevent water intrusion.
Electrical Guidelines
The power range requirement for operating the MW810 Mobile Workstation is 13.8 VDC +/
- 20% in a 12V battery, 16.5A (maximum) system, negative ground vetting or 27.6 VDC +/- 
20% in a 24V battery, 10A (maximum) system, negative ground vetting.
Be sure that the vehicle’s electrical system is in good condition. Faults in the alternator and 
ignition system can be a source of severe Radio Frequency Interference (RFI) and can result 
in operating problems. Correct any problems in the alternator output, ignition system, and 
check the battery condition before beginning the installation.
The vehicle must have an alternator that can produce a high-current output at low speed 
(below 18 m.p.h. or 29 km/h) and in an idle state. It also needs the highest rated heavy-duty 
battery available for the vehicle. The power cables of the MW810 Mobile Workstation 
should be directly connected to the power system of the vehicle. 
Ground Polarity
The MW810 Mobile Workstation should operate only in negative ground electrical systems. 
Check the ground polarity of the vehicle before starting the MW810 Mobile Workstation 
installation to verify that the polarity is correct. Accidentally reversing the polarity will not 
damage the MW810 Mobile Workstation, but will cause the cable fuses to blow.
Due to advanced vehicle assembly techniques, different parts of the vehicle chassis may not 
be connected to the battery negative terminal. Connecting the ground leads of several devices 
with a common power supply into different location on the chassis, may cause GROUND 
potential differences between these locations and damage the MW810 Mobile Workstation or 
any other installed equipment.
FIRST CHECK that the vehicle chassis point to which you are about to connect the 
negative lead is properly connected to the battery negative terminal. If the chassis is not 
properly grounded, connect the negative lead directly to the battery's negative terminal. 
When the CPU Box and the display are mounted on a Gamber Johnson mount or next to each 
other, use a 10AWG ground wire to connect between the body of the CPU Box and the 
DO NOT install the workstation in a vehicle with a positive-ground electrical system.
!
Caution
Avoid using power Battery Saver relays that cut-off power ruthlessly between the 
MW810 Mobile Workstation main power and the power system of the vehicle. 
Uncontrolled power cut-off can damage the MW810 Mobile Workstation 
operating system, cause loss of data and may require re-imaging of the hard 
drive. If a power cut-off device is used in order to conserve vehicle battery life, 
consult a qualified Motorola Solutions authorized installation shop or contact the 
Motorola Solutions System Support Center for assistance.
!
Caution