Dacor DCT365WLPH デザインガイド

ページ / 4
PLANNING
GUIDE
www.Dacor.com      Phone: (800) 793-0093  
Specifications subject to change without notice.
Install all appliances according to accompanying installation instructions.
4.19
Cabinet and Countertop Layout
 warning
•  To reduce the risk of personal injury caused by reaching over 
a hot appliance, avoid locating cabinet storage space directly 
above the cooktop. 
•  Failure to meet or exceed the maximum and minimum 
dimensions/clearances stated in these instructions may result 
in a fire hazard.
•  Follow the countertop manufacturer’s instructions regarding 
the minimum corner radius, use of heat reflective tape, 
reinforcement of corners, etc.
Carefully check the location where the cooktop will be installed. For 
best performance, the cooktop should be placed away from drafts that 
may be caused by doors, windows and heating and air conditioning 
outlets.
This appliance is to be used in conjunction with a suitable vent hood.
mINImUm rEqUIrED CLEArANCEs AroUND ThE CookToP
(a) Minimum
(a) recommended
36” (914 mm)
42” (1067 mm)
Allow a minimum ¼” (6 mm) clearance between the bottom of the 
cooktop chassis and all combustible surfaces, including the upper 
edge of a drawer installed below the cooktop.
The gas supply piping, gas shut-off valve and the electrical outlet 
must be located so they do not interfere with the cooktop when it is 
installed. If installing another appliance in the  cabinet below, allow for 
the routing of gas and electrical service behind it.
The installation must allow for the following:
Access to the gas shut-off valve and regulator when the unit is 
installed.
Access to the electrical outlet when the cooktop is in place. The 42” 
(106.7 cm) power cord must be able to reach the electrical outlet
Access to the underside of the cooktop for service and inspection 
purposes
Clearance inside the cabinet to allow for proper hold down bracket 
installation.
To allow access to the utilities and cooktop bottom, a fixed shelf should 
not be installed below the cooktop. See the following pages for countertop 
cutout dimensions.
DCT365
¼” (6 mm)
mimimum clearance
to combustible
surfaces
 35 ¼” (89.5 cm)*
 * Allows for clearance between hold down brackets
13" max.
3
(33.0 cm)
3
 Not applicable for cabinets more than a horizontal distance of  
  
 
5 ½” (14.0 cm) from edge of cooktop. Allow 6 
7
/
8
” (17.5 cm) 
  
 
from cutout edge.
A
  18" min.
1, 3
(45.7 cm)
 1 
5
/
8
" min. 
(4.1 cm)
Combustible 
surface to rear
Combustible overhead 
cabinets
30" min.
1, 2
(76.2 cm)
See cutout dimensions
See cutout
dimensions
2
 If installing with an overhead vent hood, also check the hood 
  
 
specifications for minimum required clearances.
1
 Measured from the cooking surface (top of cooktop grate).
Cabinet tolerances: +1/16”, -0,  (+1.6 mm, -0) 
unless otherwise stated
Document # PG04-006
Revised 09/29/10   Page 3/4
36” Wide, Distinctive  
series Gas Cooktop
PRELIMINAR
Y