SecurStor 16i Installation and Hardware Reference Manual  
 
3-2 
 
ƒ  Inter-Integrated Circuit (I
2
C): The I
2
C serial bus is used to connect various 
temperature sensors and presence detection circuits within the chassis.   
Subsystem monitoring is a necessary part of subsystem management. If failure events or other 
disruptive events are detected and reported, the subsystem managers must take appropriate 
actions to rectify the problem. Failure to act in a properly specified manner to a system event 
(like overheating) can cause severe and permanent damage to the subsystem.  
 
3.2  Status-indicating LEDs 
3.2.1  Brief Overview of the LEDs 
The following devices all come with LEDs that inform subsystem managers about 
the operational status of the component.  
Component 
LEDs per Unit 
Total LEDs 
Definition 
Drive Trays 
2 32 
See 
Section 0 
Controller 
Module 
7  
See Section 0 
Ethernet 
Ports 
2 10 
(5 
ports) 
 
BBU Module
 
(if BBU is 
installed) 
1 1 
See 
Section 0 
PSU Module 
1 2 
See 
Section 0 
Cooling 
Module 
2 4 
See 
Section 0 
Table 3-1: LED Distribution
 
LED definitions are given in the following sections. 
 
3.2.2 Drive 
Tray 
LEDs 
Two (2) LED indicators are located on the right side of each drive tray. (See Figure 
3-11) Refer to Table 3-2 for the LED definitions. When notified by a drive failure 
message, you should check the drive tray indicators to find the correct location of the 
failed drive. Replacing the wrong drive can fail two members of a logical array 
(RAID 3/5) and thus destroy data in the array.  