35 
Code  Description 
When Error Occurs 
Action Required 
Eb 
07 
Object failed 
validation 
After software object 
download complete and FP is 
displayed 
After a successful software 
object download and the 
terminal is reset 
Contact the headend 
operator 
No action required 
because the terminal 
repeats the software 
object download 
Eb 
08 
Reserved  
None 
Eb 
09 
Check failed 
Reset within two minutes of a 
complete software object 
download 
No action required 
because the terminal 
repeats software 
object download 
process 
Eb 
10 
SUDB 
recreation 
After plugging the terminal 
into an electrical outlet to 
begin the boot cycle 
None 
Eb 
11 
Failed to lock 
OOB frequency 
After cycling twice through the 
OOB frequencies (LED then 
displays Eb 02, indicating 
the software object download 
was unsuccessful.) 
Ensure proper cable 
connections 
Eb 
12 
No COAC 
message 
received 
After cycling twice through the 
OOB frequencies (LED then 
displays Eb 02, indicating 
the software object download 
was unsuccessful.) 
Contact headend 
operator 
Eb 
13 
No DLC 
message 
received 
After cycling twice through the 
OOB frequencies (LED then 
displays Eb 02, indicating 
the software object download 
was unsuccessful.) 
Contact headend 
operator 
Eb 
14 
Bad object type 
or class 
After the LED displays dl, 
indicating failed during 
attempted download 
Contact headend 
operator 
Eb15  No matching 