Mitsubishi Electronics DX-TL1600EM ユーザーズマニュアル

ページ / 86
85
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Specifications
ENGLISH
Specifications
Rated Power Supply:
AC 100-240V  50/60Hz
Rated Input:
1.0 - 0.5A (100-240V)
Color System:
PAL-type color system.
Operating Temperature:
41
°
F-104
°
F (5
°
C to 40
°
C).
Relative Humidity:
Max.80(%)
Altitude:
Max.2000(m)
Dimensions:
425(Width) x 380(Depth) x 113(Height)(mm).
Weight:
7.5kg
Recording System
Digital recording system with JPEG compression method.
  Sampling
13.5MHz
  Data Compression
JPEG
  Compression Unit
Field
Resolution
684 x 288
Recording Device
60GB HDD
Video Input:
16 Input BNC-Connector:
1.0 V(p-p), 75 ohms.
Monitor Output:
S-Connector:
Y-Signal: 1.0 V(p-p), 75 ohms.
C-Signal: 0.286 V(p-p), 75 ohms.
BNC-Connector:
1.0 V(p-p), 75 ohms.
Throughout Output:
16 Output BNC-Connector:
1.0 V(p-p), 75 ohms.
Timer Program:
8programs-Daily start and stop time for one week x3set.
Memory Backup:
Lasts for more than 1 month.
CONNECTORS
POWER ON Input:
Terminal for power ON.
LOW: POWER OFF / HIGH: POWER ON
POWER OFF Input:
Terminal for power OFF.
LOW: POWER OFF
ALARM IN(1-16) Input:
Terminal for starting alarm recording.
CLOCK ADJ Input:
Terminal for adjusting clock.
REC Input:
Terminal for start recording.
GND:
Terminal for ground.
ALARM OUT Output:
Terminal for output while alarm recording is under way.
MODE OUT Output:
Terminal for indication of recording selected mode.
DC 5V OUT Output:
Terminal for DC 5V OUT.
CALL OUT/CALL OUT GND:
Terminal for external warning device.
Rating:
ALARM OUT /
Active:
“Low” Level.
Max. Drive current 7mA DC.
MODE OUT
Non active:
Open.
Max. Voltage +24V DC.
ALARM IN / CLOCK ADJ /
Active:
When terminals are short-circuited
REC
or “Low” Level voltage is applied.
Non active:
Open.
CALL OUT /
Active:
ON.
Max. Drive current 7mA DC.
CALL OUT GND
Non active:
Open.
Max. Voltage +24V DC.
RS-232C
RS-232C (D-SUB 9pin) terminal for connection with personal computer.
SCSI
SCSI2 (Half pitch 50pin) terminal.
Accessories
AC power cord (for U.K / for the Continent)
  2
Ferrite core
  3
Cable tie
  3
Weight and dimensions shown are approximate.
Design and specifications are subject to change without notice.
<Interface circuit inside the unit>
5V
5V
10k
Ω
22k
Ω
Input
terminal
0.047
µ
F
GND
POWER ON/POWER OFF/
ALARM IN/REC/CLOCK ADJ
Input terminal 
• Input Circuit
<Interface circuit inside the unit>
Output terminal
GND terminal
ALARM OUT/MODE OUT Output terminal 
• Output Circuit
<Interface circuit inside the unit>
CALL OUT terminal
CALL OUT GND terminal
CALL OUT output terminal 
• Output Circuit