APPENDIX 2 COMPARISON OF THE AD75 VERSIONS 
Appendix 2.1 Comparison between AD75P1/2/3 and AD75P1-S3/2-S3/3-S3 
The following table compares the A1SD75P1/2/3 and AD75P1/2/3 with the 
A1SD75P1-S3/2-S3/3-S3 and AD75P1-S3/2-S3/3-S3. 
 
A1SD75P1/2/3, AD75P1/2/3 
Item 
A1SD75P1-S3/2-S3/3-S3 
AD75P1-S3/2-S3/3-S3 
Version R  
or later 
Version Q  
or earlier 
Pulse output logic selection 
Possible (select positive or 
negative logic) 
Not possible (positive logic) 
Block transfer of positioning data 
Possible 
Not possible 
Accel/decel time setting 
Selection between 1 to 
65635ms and 1 to 
8388608ms possible 
1 to 65635ms 
JUMP instruction 
Available 
Not available 
Continuous operation suspension 
function 
Available Not 
available 
Starting bias speed setting 
Possible 
Possible 
Not possible 
Stepping motor mode selection 
Possible 
Possible 
Not possible 
Selection of operating speed for 
original point shift 
Possible Possible 
Not 
possible 
Dwell time setting for OPR retry 
function 
Possible Possible 
Not 
possible 
Accel/decel time changing function 
for speed change 
Possible Possible 
Not 
possible 
Current value clearing function for 
speed/position switching control 
Possible Possible 
Not 