Multiquip GB114BS/BP ユーザーズマニュアル

ページ / 46
PAGE 18 — GB114BS/BP GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #3 (01/06/09) 
OPERATION
RAISING THE EXTENSION POLE
Before raising the extension pole, make sure the 
1. 
T-handle bolt lock (Figure 6-O) is securely tightened. 
This will prevent the balloon/lamp assembly from falling 
off. In addition make sure that the lamp power cable 
is connected to the mating end of the power source 
cable.
Raise extension pole (Figure 6-L) to desired height. 
2. 
Watch out for any overhead obstructions.
Using 19 mm wrench, tighten extension clamp bolt 
3. 
(Figure 6-Q) securely. Keep wrench in a safe place 
where it will not get lost.
  DANGER
ALWAYS make sure the area 
above the lighting system is 
open and clear of overhead 
p owe r   l i n e s     a n d   o t h e r 
obstructions.  Contact with 
overhead power lines or other 
obstructions could result in 
equipment damage,  Serious 
Injury or Death!
  DANGER
When raising the extension pole, ALWAYS 
be on the lookout for overhead obstructions 
such as high voltage power lines. The 
possibility exists of electrocution, even 
death! if the lighting system comes in 
contact with high voltage power lines. 
APPLYING POWER
Make sure the power ON/OFF switch (Figure 10) 
1. 
located near the bottom of the ballast is in the OFF 
position.
 Power OFF/ON Switch (Off Positon)
Figure 10. 
If using a power source (Figure 11) other than a 
2. 
portable generator, plug the AC power cord from the 
ballast into a 120 VAC, 60 Hz receptacle that is 
protected by a at least a 15 amp circuit breaker.
Applying 120 VAC Power
Figure 11. 
BALLAST
OFF
ON/OFF
SWITCH
EXTERNAL
SINGLE-PHASE
(120 VAC)
POWER SOURCE
RECEPTACLE
BALLAST
CONNECT
TO BALLOON
POWER
CABLE
AC POWER
CORD
 NOTICE
If using a portable generator, start the generator as 
referenced in the "Start-up Section" of the supplied 
generator manual.
Once the generator has started, plug the AC power cord 
from the ballast (Figure 11) into a GFCI receptacle on 
the generator.