Mitsubishi Electronics FR-A500 ユーザーズマニュアル

ページ / 257
232
8.1.2
Plug-in dedicated options
z
z
z
z
 Plug-in options
Note: 1. Three plug-in options may be mounted at the same time (the number of the same options
mountable is only one, and only one of the communication options may be mounted.)
2. The FR-A5AX (12-bit digital input) is required separately to input the stop position command
externally for orientation control.
3. Profibus is a registerd trademark of PROFIBUS User Organization.
4. DeviceNet
TM
 is a registered trademark of ODVA(Open DeviceNet Vender Association, Inc.).
5. CC-Link is a registered trademark of CC-Link Partner Association. CC-Link stands for Control &
Communication Link.
6. Modbus plus is a registered trademark of Schneider Electric.
Name
Type
Function
12-bit digital input
FR-A5AX
Input interface used to set the inverter frequency accurately using external 3-digit BCD or 
12-bit binary-coded digital signals.
Gains and offsets can also be adjusted.
Digital output
FR-A5AY
Among 26 standard output signals of the inverter, this option outputs any 7 selected signals 
from open collector output terminals.
Extension analog output
Outputs extra 16 signals which can be monitored on the FM and AM terminals such as 
output frequency, 
20mADC or 5V(10V)DC meter can be connected.
Relay output
FR-A5AR
Among 26 standard output signals of the inverter, this option outputs any 3 selected signals 
from relay contact output terminals.
Orientation, encoder 
output (Note 3)
FR-A5AP
Used with a position detector (pulse encoder) installed on a machine tool spindle to stop 
the spindle in position (orientation control).
The motor speed is detected by the pulse encoder and this detection signal is fed back to 
the inverter to automatically compensate for speed variation. Hence, the motor speed can 
be kept constant if load variation occurs.
The current spindle position and actual motor speed can be monitored on the operation 
panel or parameter unit.
Pulse train input
A pulse train signal can be used to enter the speed command to the inverter.
Comm
unicat
ion
Computer link
FR-A5NR
Operation/monitoring/parameter change of the inverter can be performed under the control 
of a user program from a computer, e.g. personal computer or FA controller, connected by 
a communication cable.
Relay output
Any one output signal can be selected from among the standard output signals of the 
inverter and output as a relay contact (contactor) signal.
Profibus DP
(Note 3)
FR-A5NP
FR-A5NPA
Operation/monitoring/parameter change of the inverter can be performed from a computer 
or PLC.
DeviceNet
TM
(Note 4)
FR-A5ND
Operation/monitoring/parameter change of the inverter can be performed from a computer 
or PLC.
CC-Link (Note 5)
FR-A5NC
Operation/monitoring/parameter change of the inverter can be performed from a PLC.
Modbus Plus 
(Note 6)
FR-A5NM
Operation/monitoring/parameter change of the inverter can be performed from a computer 
or PLC.