KitchenAid 1955 インストール手順

ページ / 32
location
If possible, the range should be located to avoid the main 
“traffic path” through the kitchen or where an open door 
might block a passageway or create an awkward working 
situation. If possible, it should be so located where cabinet 
working space is available on either side. Drafty locations 
should be avoided to prevent gas burner outage and poor 
air circulation.
temperatures
To cook, you must have heat. Some parts of the range are 
therefore going to get warm or even hot. Consider this in 
choosing a range location. Do not leave children alone or 
unattended  near  the  range  when  it  is  in  use.  Let  burner 
grids  and  other  surfaces  cool  before  touching  them  or 
leaving them where children can reach them.
clearances
This  range  may  be  installed  with  adjacent  surfaces 
touching the base cabinets and the back flush with the back 
wall.  Models  1955  and  1956  gas  ranges  require  a  CGA/
AGA  approved  stainless  steel  gas  flex  line  or  a  flexible 
copper coil 1/2” in diameter and at least three feet long so 
the range can be moved for service.
To  eliminate  the  risk  of  burns  or  fire  by  reaching  over 
heated  surface  burners,  cabinet  storage  above  the  range 
should  be  avoided.  If  overhead  storage  is  unavoidable, 
clearances  between  the  cooking  surface  and  unprotected 
wood  or  metal  overhead  cabinets  must  be  no  less  than 
32”.  The  clearances  on  electric  models  between  the 
cooktop and unprotected overhead cupboards is 30”. This 
distance  may  be  reduced  to  24”  when  the  bottom  wood 
or metal cabinets are protected by not less than 1/4” thick 
flame retarding millboard covered with not less than No. 
28MSG  sheet  steel,  0.015”  thick  stainless  steel,  0.024” 
thick aluminum or 0.020” thick copper.
note:  Clearances  specified  to  combustible  construction 
(walls  and  materials)  are  based  on  a  temperature  rise  of 
wood resulting from appliance operation. These clearances 
are suitable for walls of studding, lath and plaster or other 
types  of  combustible  material  which  have  a  density  of 
20 lbs.  per  cu.  ft.  or  more.  No  evaluation  of  clearances 
has been made for low density cellulose, fibre board and 
similar materials which have a density of less than 20 lbs. 
per cu. ft., nor to plastic tiles or sheeting.
The maximum depth of upper cabinets installed above the 
range is 13”.
See the 
minimum clearances chart for electric and gas 
models below.
minimum clearances to combustibles
 
 
c  D  e 
f
 All Model Electric 1954  0” 
0”  30”  0”  0”  13”
 max.
  Combo Model 1954  3”
 
min.  
ht. 18”
 3”
 
min.  
ht. 18”
 32”  0”  0”  13”
 max.
  All Gas Model 1956  3”
 
min.  
ht. 18”
 3”
 
min.  
ht. 18”
 32”  0”  0”  13”
 max.
1 = End of section of overhead cabinet
2 = Overhead center cabinet
3 = End wall or divider
exhaust hood Dimensions – 30” W x 22” D x 6” H 
Hood should be installed 28” to 30” from the bottom of 
hood to the range cook top. See Full Installation information 
in Exhaust Hood Manual.
It is the responsibility of the installer to comply with the 
installation clearances specified in this manual.
cabinet openings
This range will fit into a 30 1/4” cabinet opening.
leveling your range
Place rack in oven. Place level on rack, first side to side, 
then front to back.
If the range is not level, adjust leveling legs up or down with 
pliers or your fingers until range is level.
NOTE:  Oven  must  be  level  for  satisfactory  baking 
performance.
6