Mitsumi electronic HC3800 ユーザーズマニュアル

ページ / 48
EN-44
This projector has two indicators, each of which shows the operation condition of the projector.
The following offer solutions to possible problems. If these problem persist, turn the projector off and consult your 
dealer. 
POWER indicator
STATUS indicator
Normal condition
POWER
STATUS
CONDITION
NOTE
Steady red
Off
Stand-by
Steady green
Blinking green
Lamp stand-by (about 1 minute)
The POWER button cannot be used to 
switch between on and off.
Steady green
Steady green
The power is on. (Normal condition)
Abnormal condition
POWER
STATUS
CONDITION
POSSIBLE SOLUTION
Steady green
or
Steady red
Blinking orange
Abnormal temperature
The ventilation grilles are clogged with dust or 
dirt.
The room temperature is high.
Clean the ventilation grilles.
Relocate the projector to a cooler 
place.
Steady red
Blinking green
The protection circuit is working or the lamp is in an 
abnormal condition.
Wait until the STATUS indicator goes 
out, then press the POWER button.
If the above solution is not effective, 
replace the lamp.
Steady green
Blinking green/red
Lamp operation time warning. (Total lamp operation 
time reached 750 hours*
1
 while the power was on.)
Replace the lamp.
Change with a new lamp if this problem 
recurs.
Steady red
Blinking red
Lamp operation time warning. (Total lamp operation 
time reached 750 hours*
1
 while the power was off.)
Steady red
Steady red
Lamp operation time warning. (Total lamp operation 
time reached 5000 hours*
1
*
 while the power was 
off.)
Blinking green/red
Off
The lamp cover isn’t closed.
Close the cover correctly.
Blinking green/red
Steady or
 
Blinking
Abnormal.
Contact your dealer.
*1:  Duration when LAMP MODE of the INSTALLATION menu is set to LOW. When it is set to STANDARD, this duration will be 
shorted.
*:  When LAMP MODE is set to STANDARD, this duration will be shorted up to 000 hours.
Indicators