Motorola 3460 ユーザーズマニュアル

ページ / 188
3460 Fast’R
1-29
Installing a Second DC Power Module
You can install a second DC power module, while the AccessWay is 
operating, as follows. 
Installing a Second DC Power Module
Step
Action
1.
Warning
The AccessWay enclosure power module 
should be installed and removed only by a 
trained service person.
Avertissement
Le module d’alimentation électrique de 
l’enceinte AccessWay doit être installé et 
retiré par un réparateur expérimenté.
Warnung
Ein- und Ausbau des AccessWay 
Schaltschranks ist von einem geschulten 
Wartungstechniker vorzunehmen.
2.
Remove the blank panel that covers the right power module slot 
by loosening the screws at the top and bottom (Figure 1-14).
3.
Slide the second power module into the right AccessWay power 
module slot. Ensure that its front rail is flush with the adjacent 
power module rail.
Tighten the power module screws.
4.
Optionally, connect a remote alarm monitoring device to the 
AccessWay ALARM 2 terminals, to alert you to a fault in the 
DC output voltage. To do so, refer to the “Connecting the 
AccessWay to DC Power Supply” section on page 1-25. 
5.
Verify that the LEDs on the power modules are lit. The LEDs 
indicate the presence of input voltage and the status of output 
voltage.