30
NOTE: Pressing keyboard (touchpad) key “A,” “B,” “C,” “D,” and “F” will also start the dryer.  The
six (6) preprogrammed drying cycles (“A” through “F”) have been stored in the
microprocessor controller (computer) memory.  Refer to the Programming Manual supplied
with the dryer for more specific operating instructions.
NOTE: The dryer can be stopped at any time by opening the main door or by pressing the “CLEAR/
STOP” red key.  To restart the dryer, press the “ENTER/START” green key or a
preprogrammed cycle key (i.e., “E”).
NOTE: Selection (settings) changes can be made at any time during the drying cycle by pressing the
“CLEAR/STOP” red key twice.  The L.E.D. (light emitting diode) display will return to
“REAdY” at which time a new cycle selection can be made.
b. Dual Timer Dryers
1) Select Drying Time and Cool Down Time desired...
a) Turn Heat Timer clockwise (CW) to the desired time (i.e., 1 minute to 60 minutes)
b) Turn Cool Down Timer clockwise (CW) to the desired time (i.e., 0 minute to 30 minutes)
2) Select Drying Temperature (“HI TEMP,” “LO TEMP,” or “PERM PRESS”).
3) Push “Push To Start” Switch...
a) Dryer will now start.
4) To stop the dryer, open the main door.
K.  SHUT DOWN INSTRUCTIONS
If the dryer is to be shut down (taken out of service) for a period of time, the following must be performed:
1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.
2. Discontinue the heat supply:
a. SHUT OFF external gas supply shut-off valve.
b. SHUT OFF internal gas supply shut-off valve located in the gas valve burner area.