Philips P89LPC902 ユーザーズマニュアル

ページ / 114
Philips Semiconductors
User’s Manual - Preliminary -
P89LPC901/902/903
CLOCKS
2003 Dec 8     
29
If CCLK is  8MHz or slower, the CLKLP SFR bit (AUXR1.7) can be set to ’1’ to reduce power consumption. On reset, CLKLP is 
’0’ allowing highest performance access. This bit can then be set in software if CCLK is running at 8MHz or slower.
Figure 2-2: On-Chip RC Oscillator TRIM Register
Watchdog Oscillator Option
The watchdog has a separate oscillator which has a nominal frequency of 400KHz. This oscillator can be used to save power 
when a high clock frequency is not needed. 
External Clock Input Option - P89LPC901
In this configuration, the processor clock is derived from an external source driving the XTAL1 / P3.1 pin. The rate may be from 
0 Hz up to 12 MHz. The XTAL2 / P3.0 pin may be used as a standard port pin or a clock output.
TRIM
Address: 96h
Not bit addressable
Reset Source(s): Power-up only
Reset Value: On power-up reset, ENCLK = 0, and TRIM.5-0 are loaded with the factory programmed value.
BIT
SYMBOL
FUNCTION
TRIM.7
-
Reserved.
TRIM.6
ENCLK
When ENCLK =1, CCLK/ 2 is output on the XTAL2 pin (P3.0) provided that the crystal 
oscillator is not being used.  When ENCLK=0, no clock output is enabled.(P89LPC901).
TRIM.5-0
Trim value.
Note: on reset, the TRIM  SFR is initialized with a factory preprogrammed value. When setting or clearing either the ENCLK 
or RCCLK  bits,  the user should retain the contents of bits 5:0 of the TRIM register. This can be done by reading the contents 
of the TRIM register (into the ACC for example), modifying bits 6 or 7, and writing this result back into the TRIM register. 
Alternatively,  the "ANL direct" or  "ORL direct" instructions can be used to clear or set bit 6 or 7of the TRIM register.
7
6
5
4
3
2
1
0
-
ENCLK
TRIM.5
TRIM.4
TRIM.3
TRIM.2
TRIM.1
TRIM.0