Overview of Navigation and Controls 
 
54 
PTZ Setup 
Note 
The camera video should be in the current screen. 
Before setup, check whether the following connections 
are right: 
•  PTZ and decoder connection  
•  Decoder address setup 
•  Decoder A  (RS485 +) /  B  (RS485  -)  line connects with 
DVR A/B line 
Boot up the DVR, and input the user name and password. 
In the main menu, select Setting
Pan/Tilt/Zoom. The interface is shown 
as in 
. Here you can set the following items: 
• 
Channel:  Select the channel
  connected with the speed dome video 
port.
 
• 
Protocol: Select the corresponding PTZ protocol (such as PELCOD). 
• 
Address: 
Identical to the device address set in the speed dome. 
Default address is 1. 
• 
Baud rate:  Select corresponding baud rate. 2400 for Pelco-D 
protocol. 
• 
Data bits: Select corresponding data bits. Default value is 8. 
• 
Stop bits: Select corresponding stop bits. Default value is 1. 
• 
Parity: There are three options: Odd/Even/None. The default  value 
is none.