Motion Detection 
• 
Enable/Disable:  1 = Enabled, 0 = Disabled 
• 
Activity or Intrusion Detection:  I = Intrusion, A = Activity 
• 
Sensitivity:  1 through 10 
• 
Relay Output: None, 1, 2, 1+2 
• 
Link to Event: Yes or No 
• 
Rejection Ratio:  High, Medium, or Low 
• 
Target Size:  1 through 256 
• 
Alarm Camera:  1 through 4, 10 or 16 
 
View Screen 4 
Record Rate 
• 
Event Camera Settings:  T = Timelapse, E = Event, ET = Event and Timelapse 
• 
Timelapse Record Rate:  In pictures per second (pps). 
• 
Event Record Rate:  In pictures per second (pps). 
• 
Pre Event Duration:  0 to 5 seconds. 
• 
Post Event Duration:  0 to 200 seconds. 
• 
Acitvity Record Rate:  In pictures per second (pps). 
• 
Record Quality:  High, Medium, or Low. 
 
View Screen 5 
Record Timer 
• 
DAY:  1-31, Mon, Tue, Wed, Thu, Fri, Sat, Sun, Mon-Fri, Sat-Sun, Mon-Sun 
• 
Start:  Time (HH:MM) 
• 
Stop:  Time (HH:MM) 
• 
Macro:  Macro Number, On or Off 
 
View Screen 6 
• 
Time and Date Display A:  On or Off. 
• 
Time and Date Display B:  On or Off. 
• 
Time Format 
• 
Date Format 
• 
Titles Display A:  On or Off. 
• 
Titles Display B:  On or Off. 
• 
Master Clock:  Yes or No. 
• 
Multiscreen Dwell:  In seconds. 
• 
Full Screen Dwell:  In seconds. 
• 
Record Mode: No Overwrite, Write Once, or Continuous. 
• 
Auto Disable:  On or Off. 
• 
Indicate Detection:  On or Off.