Lucent Technologies 555-661-150 ユーザーズマニュアル

ページ / 360
MERLIN LEGEND Communications System Release 6.1
Network Reference  
555-661-150  
Issue 1
August 1998
Network Management 
Page 5-8
General Programming in Private Networks 
5
facility. In the diagram above, notice that System B has three 100D 
modules (and therefore three ports) to provide synchronization. (See the 
diagram above.)
NOTE:
If a DEFINITY ECS or DEFINITY ProLogix Solutions system is 
included in the private network and has functional digital PSTN 
facilities, it should provide the clock synchronization source.
2.
If a star configuration is linked by tandem digital facilities and has no in-
service digital PSTN facilities connected to any switch, the primary clock in 
System B provides clock synchronization for the private network. (See the 
diagram above.)
3.
A private network in a series or combination star/series configuration linked 
by tandem PRI facilities has no in-service digital PSTN facilities connected 
to any switch. System B acts as the primary private network source. If 
System B has a total failure, System C provides clock to System D
. (See 
the diagram above.)
System Date and Time
5
For more information on system date and time, see 
System Programming. When 
a MERLIN LEGEND Communications System switch is in a private network with 
one or more other MERLIN LEGEND Communications Systems or with one or 
more DEFINITY ECS or DEFINITY ProLogix Solutions systems, Station Message 
Detail Recording (SMDR) reports may report outgoing calls using more than one 
call record, depending upon how SMDR is programmed and how calls are routed. 
If SMDR is reporting outgoing calls and users are employing private network lines 
to make these calls, ensure that the system date and time are set accurately on 
each system that carries these calls. As you examine call reports, you may need 
to be aware of time zone differences among private networked system locations.
System A
System C
System B
tandem
PRI
tandem
PRI
100D
100D 100D
100D
Primary: Loop B
Secondary: Local B
Tertiary: ______
Primary: Local A
Secondary: Local B
Tertiary: Loop B
Primary: Loop B
Secondary: Local B
Tertiary: _____
System A
System C
System B
tandem
PRI
tandem
PRI
100D
100D 100D
100D
loop
local
loop
100D
System D
loop
100D
tandem
PRI