 Figure 3.5:   iPump 562 OSD Current Channel Screen
Use the 
Current Channel 
screen to set or display the channel information. 
Table 3.3: Channel Information Options 
Configure 
LNB options
LNB Setup screen
Use following steps to display 
LNB Setup
 screen on the OSD menu:
1. Press any push-button on the front-panel to display the 
Main Menu
.
2. Press the down arrow button to select 
Carrier Settings
.
3. Press 
Enter
.
4. Press the down arrow button to select 
LNB Setup
.
5. Press 
Enter
 details the 
LNB Setup
 screen.
6. To navigate the screen, use down arrow and 
Enter
 to select an option. When the 
corresponding value of that option on the left is selected, use up or down buttons to 
set to the desired setting. Press 
Enter
 when done. Move to the next option using up 
or down button or left arrow to exit to the previous menu level.
Option
Possible values
Comments
Preset
Perm, Command, Last 
Success or Current
Only Perm option allows other options to be set. 
The channel set using the 
Compel
 Command.
Modulation
QPSK/S2QPSK/S28PSK
-
FEC Ratio
1/2, 2/3, ¾, 5/6, 7/8
-
Frequency
Data Rate
Symbol Rate
Automatically calculated and displayed only
Program
Set to the desired program # in the carrier
Tag Site
The tag #15 is a special value