ユーザーズマニュアル目次General Safety Guidelines21.0 Product Description51.1 General Product Information51.1.1 Customer-Supplied Equipment and Ductwork5Figure 1 Liebert Air Economizer arrangement, typical61.2 Equipment Inspection61.3 Equipment Handling61.3.1 Handle the Liebert Air Economizer With Skid71.3.2 Move the Liebert Air Economizer With a Forklift71.4 Unpack the Liebert Air Economizer72.0 Installation82.1 General Considerations82.2 Install the Liebert Air Economizer—Preliminary Steps82.2.1 Position the Liebert Air Economizer on a Liebert CW8Secure the Liebert Air Economizer to the Liebert CW82.2.2 Position the Liebert Air Economizer on a Liebert DS9Figure 2 Dimensions—Liebert Air Economizer and Liebert CW models CW106D/114D10Figure 3 Dimensions—Liebert Air Economizer and Liebert CW models CW026D-CW084D11Table 1 Dimensions—Liebert Air Economizer and Liebert CW models CW026D-CW084D11Figure 4 Dimensions—Liebert Air Economizer and Liebert DS downflow units, 28-105kW (8-30 tons)12Table 2 Liebert DS model dimensional data, 28-105kW (8-30 tons)122.3 Wiring the Liebert Air Economizer132.3.1 Wire the Dampers14Figure 5 Damper wiring connections—Liebert DS and Liebert CW units142.3.2 Outdoor Air and Return Air Temperature and Humidity Sensor Connections15Figure 6 Temperature and humidity sensor connections—Liebert DS and Liebert CW15Figure 7 Supply limit thermistor wiring and restricted airflow switch location162.4 Adjust the Restricted Airflow Switch163.0 Installation Checklist174.0 Operation184.1 Operational Condition194.1.1 Normal Operation19Figure 8 Operational ranges for chilled water systems and for compressor/chilled water systems194.2 System Overview19Figure 9 Air flow pattern of a Liebert Air Economizer system204.2.1 Out of Service21Figure 10 Liebert DS setpoints screen, page 4 of 622Figure 11 Service/Economizer, page 1 of 323Figure 12 Outdoor sensor data screen24Figure 13 Damper settings and limits screen254.2.2 Fan Speed Control26Reduced Economizer Air Flow264.2.3 Variable Speed Fan Operation (VFD and EC Fan)264.2.4 Disable the Liebert Air Economizer26Figure 14 Deactivation switch264.3 Control Menu Settings264.3.1 Liebert Air Economizer Status Screen274.4 Temperature Control Modes—P and PI274.4.1 Proportional Control274.4.2 Proportional Integral Control274.4.3 Integral Wind-up274.4.4 Controller Tuning28Figure 15 Liebert iCOM Wellness menu, page 9295.0 Maintenance306.0 Troubleshooting31Table 3 Liebert Air Economizer troubleshooting31サイズ: 2.91MBページ数: 32Language: Englishマニュアルを開く