Alliance Laundry Systems LGS19A 사용자 설명서

다운로드
페이지 52
504607
17
Location Requirements . . .
Select a location with a solid floor.
No other fuel burning appliance should be installed in 
the same closet with the dryer.
The dryer must not be installed or stored in an area 
where it will be exposed to water and/or weather.
Leveling legs can be adjusted from inside the dryer 
with a 1/4" driver. All four legs must rest firmly on the 
floor so the weight of the dryer is evenly distributed. 
The dryer must not rock.
The dryer needs sufficient clearance and an adequate 
air supply for proper operation and ventilation, and for 
easier installation and servicing. (Minimum clearances 
are shown below.)
CLOSET
DOOR
D317IE3C
FRONT VIEW
(w/o Closet Door)
SIDE VIEW
A
A
C
A
D
E
B
CENTERED
AIR 
OPENINGS (G)
(2 Openings 
Minimum)
FRONT VIEW
(Closet Door)
F
F
OUTER
WALL OF
ENCLOSURE
**42"
** NOTE: For new installations, locate top of wall vent 42 inches above floor to make venting easier to 
connect.
AREA
DESCRIPTION
FREE STANDING / ALCOVE 
INSTALLATION
(See Illustration)
CLOSET  INSTALLATION
(See Illustration)
A
Dryer sides and rear clearance
0" (0 cm)
0" (0 cm)
B
Dryer top clearance
12" (30.5 cm)
12" (30.5 cm)
C
Dryer front clearance
Not Applicable
2" (5.1 cm)
D
Exhaust duct clearance to 
combustible material
2" (5.1 cm)
2" (5.1 cm)
E
Weather hood to ground clearance
12" (30.5 cm)
12" (30.5 cm)
F
Distance from floor or ceiling to 
hole edge
Not Applicable
3" (7.6 cm)
G*
Area of centered air openings in 
closet door
Not Applicable
40 sq. in./open  (260 sq. cm)
*Louvered door with equivalent air openings is acceptable. (Minimum clearances are shown.)