Enerco TSVFR30LPT 사용자 설명서

다운로드
페이지 20
10
Installation Instructions and Owner’s Manual
Unvented LP-Gas Vent Free Room Heaters
Equipment 
Shutoff Valve
Open
Closed
Figure 15
ELECTRICAL WIRING DIAGRAM:
If any original wiring as supplied with the heater must 
be replaced, it must be replaced with type AWG 105
o
wire or its equivalent except as indicated.
WARNING: Electrical Grounding Instructions: This 
heater is equipped with a three-prong (grounding) 
plug for your protection against shock hazard and 
should be plugged into a properly grounded three-
prong receptacle. 
OPERATING YOUR HEATER
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions 
exactly, a fire or explosion may result causing prop-
erty damage, personal injury or loss of life. 
A.  This appliance has a pilot which must be lighted 
by pushing the ignitor button. When lighting the 
pilot, follow these instructions exactly.
B.  BEFORE LIGHTING smell all around the appli-
ance area for gas. Be sure to smell next to the 
floor because some gas is heavier than air and 
will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use 
any phone in your building.
Immediately call your gas supplier from a 
neighbor’s phone. Follow the gas supplier’s 
instructions.
If you can not reach your gas supplier, call the 
fire department.
C.  Use only your hand to push in or turn the gas 
control knob. Never use tools. If knob will not 
4.  Correct all leaks at once.
5.  Depressurize and relieve pressure from supply 
piping system.
Pressure Testing Heater Gas Connections:
1.  Make sure that the heater supply piping sys-
tem is connected and has been leak tested as 
described above.
2.  Make sure control knob of heater is in OFF 
position.
3.  Open equipment shutoff valve (see figure 13). 
4.  Open main gas valve on or near gas meter.
5.  Check all joints from equipment shutoff valve 
to control valve (see figure 14). Apply mixture 
of liquid soap and water to gas joints. Bubbles 
forming show a leak.
6.  Correct all leaks at once.
7.  Light heater (see Operating Your Heater, pages 
10 and 11. Check the rest of the internal joints 
for leaks. 
8.  Turn off heater (see To Turn OFF Gas to Appli-
ance, page 11.
9.  Replace lower front panel. 
Figure 13
Figure 14
Control Valve
Equipment 
Shutoff Valve
To regulated propane 
source