Sterling 882.00295.00 사용자 설명서

다운로드
페이지 72
Large Dehumidifying Dryers  
Controls 
37 
 
The DEW POINT value will give you a reading of what the actual 
process air dew point is. 
 
The area in the lower left portion of the touch screen conveys two 
lines of information relating to the overall operation of the dryer.  
The following is a list of typical machine/dryer summary status 
line text messages: 
1.  Dryer Off 
2.  Left Bed In Process 
3.  Right Bed In Process 
4.  Valve Changing Position 
5.  Autostart Timer Enabled 
6.  Autotune in Progress 
7.  Over-dry Protect Active 
8.  Left Bed Heat 
9.  Left Bed Cool 
10.  Left Bed Ready 
11.  Left Bed Failure 
12.  Left Bed Process Failure 
13.  Right Bed Heat 
14.  Right Bed Cool 
15.  Right Bed Ready 
16.  Right Bed Failure 
17.  Right Bed Process Failure 
18.  Dyer is Shutting Down 
19.  Process Offline 
 
 
 
 
 
The START BUTTON allows the user to stop and start the dryer manually.  When 
the start button is pressed, the dryer begins to operate.  The text in the button will 
change from START to SHUTDOWN.  The next time the button is pressed, the 
dryer will go into a sequence shutdown and the button text will change to 
RESTART.  The process heater will shut off, the current bed regeneration will be 
completed and then the blower will stop.  If sequence shutdown is not desired, 
turning the POWER SWITCH off will turn off all components of the dryer 
immediately and the optional conveying system will be turned off also. 
 
 
 
When the button shows ALARM, the process temperature is too hot to start the 
dryer.  When the process air temperature falls below the setpoint, the button changes 
to either START or RESTART, you may begin dryer operation. 
 
 SETTING VALUES 
By pressing and holding the numbers in the SETPOINT button, the following screen will be 
displayed: