Intended Application for Ultra-Aire 90H 
For the ideal installation, draw air from the central part of the home 
and return it to isolated areas of the home like the bedrooms, den, 
utility room, or family room. The ductwork of the existing heating 
system can be used to supply air to the home. 
2. Registrations 
The UA-90H conforms to UL STD 474 and CSA Standard C22.2 
No.92. 
3. Specifications 
Model:   
Ultra-Aire 90H  
Electrical:   
 110-120 VAC, 6.3 Amps, 60 Hz, grounded  
Capacity:   
90 pints/day @ 80°F, 60% RH  
Operating Temp.:   
56°F min., 100°F max.  
Air Flow:   
 200 CFM without external ducting  
Refrigerant Charge:   1 lb., 12 oz. R22
Duct Connections:  
Round 10" inlet, 10" outlet,
6" ventilation inlet Filter Size:  
Pleated cloth: 14" X 14" X 1" 
Unit Size (w/o duct collars):  
34
1
/
2
"L x 15
3
/
4
"W x 20
7
/
8
"H Unit 
Weight:  
92 lbs Shipping Weight: 99 lbs 
4. Installation 
4.1 Installation Checklist 
IMPORTANT
 
Prior to installation of the UA-90H, the following checklist should 
be reviewed. The UA-90H can be installed in a variety of locations 
to meet the owner’s needs, and integrate with existing forced 
air systems or existing ductwork if desired. The location choice 
is contingent on a variety of requirements not limited to: ease 
of service, controls access, drainage, filtration, power, fresh-air 
ventilation, water damage prevention, and current regulatory codes 
(ASHRAE, fire, etc). Please address all of these issues before you 
select the device’s location. 
n
  
4.1A Power Accessibility 
Unit should be located in an area where the cord’s  length (10’) 
should easily reach a 115 VAC electrical  outlet with a minimum of 
a 15 A circuit capacity. 
n
  
4.1B Space 
Location should have enough clearance to handle the unit’s overall 
dimensions as well as the necessary return/supply ductwork to the 
unit. 
n
  
4.1C Low Voltage Wiring 
Unit location should be in an area where field wiring the remote 
controls (low voltage) to the unit will be possible. 
n
  
4.1D Back-Draft Damper 
It is recommended that a back draft damper be used in the 
discharge duct of the UA-90H, especially when connecting to the 
supply ducting system. The backdraft damper prevents supply air 
from counter flowing through the UA-90H when it is not operating. 
The unit location should be chosen to allow installation of this 
accessory if requested by the end user. 
n
  
4.1E Support Structure and Suspension 
Place the UA-90H on supports to raise the base of the unit. Do not 
place the UA-90H directly on structural building members without 
vibration absorbers or unwanted noise may result. 
The UA-90H may be suspended with steel hanger straps (plumbers 
tape) or a suitable alternative from structural members, as long 
as the suspending assembly supports the UA-90H’s base in its 
entirety. Do not hang the UA-90H from the cabinet. Remember to 
place a drain pan under the unit if it is suspended above a finished 
area or above an area where water leakage could cause damage. 
4.2 Electrical Requirements 
WARNING 
WARNING: DO NOT ALLOW THE YELLOW LEAD FROM 
THE ULTRA-AIRE TO CONTACT THE RED LEAD FROM THE 
ULTRA-AIRE OR DAMAGE TO THE TRANSFORMER WILL 
RESULT. 
The UA-90H plugs into a common grounded 115VAC outlet. The 
device draws 6.3 Amps under normal operating conditions. If used 
in an area which may become wet, a ground fault interrupter (GFI) 
protected circuit is recommended. Please, consult local electrical 
codes for any further information. 
Therma-Stor LLC offers a family of control devices for use with the 
UA-90H. The controls are to be located remotely from the unit and 
located in the space to be conditioned. The controls are low voltage 
(24 volt) and should be connected to the UA-90H with low voltage 
wire (thermostat or other appropriate). 
FOR HVAC INSTALLER ONLY
4
Ultra-Aire 90H Installer’s & Owner’s Manual
5
Ultra-Aire 90H Installer’s & Owner’s Manual