HDV Series Direct Vent Gas Fireplace
V
V
V
V
V
V
V
V
D
L
E
B
C
F
B
B
B
B
B
M
I
A
A
J
H
G
A
Operable
Fixed
Closed
Fixed
Closed
Opera-
ble
K
A
A
A
G
VeNtING INStAllAtIoN 
Figure 11 - 
Horizontal Vent Termination Location
Vent Terminal
Air Supply Inlet
Area Where Terminals Not Permitted
Inside Corner Detail 
FoR HoRIZoNtAl teRMINAtIoN
MINIMuM DIStANCeS 
A =  Clearance above the grade, a veranda, porch, deck, or balcony [*1" (305 mm) minimum].   
B =  Clearance to window or door that may be opened [*1" (305 mm) minimum]. 
C =  Clearance to permanently closed window [*minimum 1" (305 mm) recommended to prevent condensation 
on window]  
 
D
 
=  Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of two () feet 
(610 mm) from the centerline of the terminal [18" (457 mm) minimum].  
E
 
=  Clearance to unventilated soffits [1" (305 mm) minimum]. Clearance to vinyl soffit [30" (762mm)]. 
F =  Clearance to an outside corner. Page 16, Figure 12  
G = Clearance to an inside corner. Page 16, Figure 12 
H =  *Not to be installed above a gas meter/regulator assembly within three (3) feet (914 mm) horizontally from 
the centerline of the regulator. 
I =  Clearance to service regulator vent outlet [*3' (914 mm) minimum]. 
J =  Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance 
[*1" (305mm) minimum]. 
K =  Clearance to a mechanical air supply inlet [*6' (189 mm) minimum]. 
L
 
=  Clearance  above  a  paved  sidewalk  or  paved  driveway  located  on  public  property  [
**
7'  (133  mm) 
minimum]. 
M
 
= Clearance  under  veranda,  porch,  deck,  or  balcony.  Page  16,  Figure  12.  [For  Canada  *1"  (305  mm) 
minimum
***
].
N =  Clearance above a roof shall extend a minimum of 4" (610 mm) above the highest point when it passes 
through the roof surface and any other obstruction within a horizontal distance of 18" (457 mm). 
As  specified  in  CSA  B149  Installation  Codes.  Note:  Local  codes  or  regulations  may  require  different 
clearances. 
**  A vent must not terminate directly above a sidewalk or paved driveway, which is located between two single-
family dwellings and serves both dwellings.   
***  Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the 
floor.
W
ARNING
Always maintain minimum clearances around vent systems. The minimum clearance to 
combustibles for horizontal vent pipe are 3” at the top and 1” at the sides and bottom 
of the vent system until the pipe penetrates the nearest vertical wall (1” required). A 
1” minimum clearance all around the pipe must be maintained at outside wall and on 
vertical runs. Do not pack the open air spaces with insulation or other materials. This 
could cause high temperatures and may present a fire hazard.
*Unless the vertical run is 7Z\x feet or higher (top vent units only), the clearances for the 
horizontal run is 1” at the top.