Enviro Meridian 사용자 설명서

다운로드
페이지 44
Installation
I
NSTALLATION
 
WITH
 E
XTERIOR
 M
OUNTED
 E
XHAUST
 B
LOWER
 - F
REESTANDING
:
The  MERIDIAN  can  be  equipped  with  an  externally  mounted  exhaust  blower  (PART  #20-070).  This 
optional kit will include all components necessary to install the exhaust blower on any external vertical 
wall surface.
Choose a location for your stove that meets the requirements stated in this manual and allows installation 
with the least amount of interference to house framing, plumbing, wiring, etc.
Included in the exterior mounted exhaust blower kit are:
1 - Exhaust blower housing box.
1 - Blower cover plate.
1 - Hardware bag
Exhaust motor must be
replaced with cover
Left side with cab side
removed
Exhaust motor
Complete assembly - Exterior
blower & housing
1.  Open  the  left  side  of  the  unit  and  the  back  grill  and 
disconnect  the  Exhaust  Blower  wires  from  the  harness.  
Remove the exhaust blower by undoing the six (6) 1⁄4 hex 
head  sheet  metal  screws  that  fasten  the  blower  to  the 
housing.
2.  Remove  the  back  grill  from  the  exterior  exhaust  vent 
housing and remove the round cover plate installed on the 
blower housing.
3.  Install the round cover plate over the gasketed opening in 
the stove where the exhaust motor was removed from.
4.  Install  the  exhaust  blower  motor  in  the  Exterior  Vent 
Housing Box onto the exhaust blower housing.
5.  Follow the procedures for I
NSTALLATION
 - H
ORIZONTAL
 E
XHAUST
 
T
HROUGH
  W
ALL
  I
NSTALLATION
  -  F
REESTANDING
.  Place  the  unit  in 
the desired location. Cut the hole in the wall at the desired 
location.  Install a wall thimble. 
6.  Drill holes in the wall thimble in the corresponding locations 
for wire and fresh air if needed.  Install wire clamps and 
feed wire through the hole in the thimble into the house. 
Tighten clamp on wire and attach green ground wire (at 
the symbol) with the screw and star washer provided. 
7.  Attach a short or an adjustable section of 3” of double wall 
pellet vent through the wall thimble to the stove. Seal all 
joints with silicone. Maintain clearances to combustibles.
8.  Apply  silicone  to  the  pipe  in  the  Exhaust  Box,  slide  the 
pipe into the exhaust vent.  Mount the Exhaust Box to the 
house. Reinstall the back grill on the Exterior Vent Housing 
Box.  Apply  normal  venting  practices  when  installing  the 
vertical vent pipe. 
9.  Connect the wires in the stove. Re-install the Left side and 
Back Grill on the stove.
10. Set  the  Slider  Damper  as  described  in  the  I
NSTALLATION
  - 
S
LIDER
/D
AMPER
 S
ETTING
“ section. 
Figure 31: Exterior Exhaust Blower. 
24