Hatco 3CS2 사용자 가이드

다운로드
페이지 20
SPECIFICATIONS
4
Form No. HHM-1103
Kilowatts 
Wire Sizing
Fuse or
Model
Voltage
(kW)
Phase
Amps
AWG*†
Circuit Breaker*
Shipping Weight
3CS2-3
208
3
1
14.5
12
20
24 lbs. (11 kg)
3CS2-4
208
4
1
19.2
12
30
24 lbs. (11 kg)
3CS2-6
208
6
1
28.8
10
40
27 lbs. (12 kg)
3CS2-3
240
3
1
12.5
12
20
24 lbs. (11 kg)
3CS2-4
240
4
1
16.7
12
30
24 lbs. (11 kg)
3CS2-6
240
6
1
25.0
10
40
27 lbs. (12 kg)
3CS2-3B
208
3
3
8.4
14
15
24 lbs. (11 kg)
3CS2-4B
208
4
3
11.2
14
15
24 lbs. (11 kg)
3CS2-6B
208
6
3
16.7
12
30
27 lbs. (12 kg)
3CS2-3B
240
3
3
7.3
14
15
24 lbs. (11 kg)
3CS2-4B
240
4
3
9.6
14
15
24 lbs. (11 kg)
3CS2-6B
240
6
3
14.5
12
20
27 lbs. (12 kg)
3CS2-8
208
8
1
38.4
8
50
27 lbs. (12 kg)
3CS2-8
240
8
1
33.3
8
50
27 lbs. (12 kg)
3CS2-9B
208
9
3
25.0
10
40
27 lbs. (12 kg)
3CS2-9B
240
9
3
21.7
10
30
27 lbs. (12 kg)
3CS2-12B
208
12
3
33.4
8
50
27 lbs. (12 kg)
3CS2-12B
240
12
3
29.0
10
40
27 lbs. (12 kg)
ELECTRICAL RATING CHART – 3CS2 MODELS
* Based upon NEC 2002 Code
† Based upon THHN wire rated 90ºC.