1-6.Trouble shooting
Before you ask for repair service, check the following points:
Error Display
State of Machine
Cool air or warm air 
does not come out.
Cause
Remote Controller 
Air flows out but it 
does not cool 
enough or heat
enough.
It does not run
Troubleshooting
The liquid crystal 
display shows that 
it is in operation.
The liquid crystal 
display shows that 
it is in the state of 
operation.
Improper temperature adjustment.
The earth leakage breaker is gone.
The fuse in the power supply is gone.
The power supply is turned OFF.
Power failure
Indoor unit operation was started anew during 
the heating and defrosting operation.
(5    10 HP only)
The restart-preventing circuit is in operation for 
3 minutes.
Can not change
to Heat mode
DIP switch1 is not correct
Change the DIP switch off to on.
(Refer to Instruction manual for Installation.)
Windows and doors are open.
There are some obstacles at the air inlet and 
outlet of the indoor and outdoor units.
The filter is filled with dust and dirt.
Turn the power supply ON.
Press the [ON/OFF] button after power restoration.
Close.
Remove.
Clean up the filter.
After checking the set temperature and inlet
temperature on the liquid crystal display, refer to
[To change room temperature] on page 107, and 
operate the adjustment button.
Put in the earth leakage breaker.
Replace fuse.
Wait for a while.
(Heating operation starts after ending defrosting
operation.)
Wait for a while.
(To protect the compressor, a 3-minute restart-
preventing circuit is built into the indoor unit.
Therefore, there are  occasions sometimes when
the compressor does not start running immedi-
ately. There are cases when it does not run for as 
long as 3 minutes.)
"ON-OFF "display is 
not   lit up
No display appears 
even when the [ON/
OFF] button is 
pressed.
Indicate
Cause
Troubleshooting
E01
Room temperature sensor open.
Automatically reset to restoration error.
E02
Room temperature sensor short.
Automatically reset to restoration error.
E03
Error input from Indoor unit or
Push the On-Off switch.(OFF to ON)
Outdoor unit.
Can not change to 
Heat mode when 
press the "MODE" key.