BUILDER'S CHOICE SERIES INSTALLATION INSTRUCTIONS
C. LOCATION AND CLEARANCES
1. APPLIANCE LOCATIONS AND SPACE
REQUIREMENTS
Figure 1 illustrates a variety of ways the appliance may
be located in a room. The Builder's Choice Series may
be installed directly on the floor or on a hearth. These
appliances  are  certified  for  installation  in  a  bedroom,
bed/sitting  room  or  in  mobile  homes  in  the  U.S.  and
Canada.
2. CLEARANCES
a. For the appliance:
Top of standoffs
Floor
Back of appliance
1/2”
Sides
1/2”
Front Face to Ceiling
30”
b. Minimum Venting Clearances (see Figure 2).
1) Horizontal  runs  off  of  the  back  of  the
appliance to the wall shield:
0” above the top of the appliance standoffs
1” sides and bottom of the vent
2) Horizontal runs inside a wall (heat shields
must be installed)
3” air space on top of the vent
1” from sides and bottom of vent
3) Vertical runs
1” air space around the vent
Figure 1 - Appliance Locations
Note: 
Dimensions  represent  minimum  space  required
for  a  centered  corner  installation. Actual  requirements
will vary with individual construction.
Figure 2 - Rear Vented Appliances Venting Clearances
WARNING!