Waterford Appliances E65-NG1 사용자 설명서

다운로드
페이지 40
28
Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove
OPTIONAL WALL
THERMOSTAT
A wall thermostat may be installed if desired.
Connect the wires as per the wiring diagrams.
Note that the wires are  connected to the "TH"
on the gas valve. Use table below to determine
the maximum wire length:
Note: Preferable if the thermostat is in-
stalled on an interior wall.
Waterford offers an optional programmable
thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.
CAUTION
Do not connect the millivolt
wall thermostat wires
to the 120V wires.
INSTALLATION
2) Remove the glass panel by loosening the 6
screws securing the glass brackets. Sup-
port the glass to prevent it from dropping
out and breaking.
3) Attach the 4 grill clips with the 4 screws but
do not tighten down at this point.
4) Place the grill into position on the front of the
door, center it in the front viewing area and
use the grill clips to hold it in place.
5) Tighten the screws on the grill clips.
6) Replace the glass and secure the glass
clips, reversing step 2)
7) Close the front door by reversing step 1).
Thermostat Wire Table
OPTIONAL REMOTE
CONTROL
Use the Waterford Remote Control Kit approved
for this unit. Use of other systems may void your
warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.
1) Choose a convenient location on the wall to
install the receiver and the receptacle box
(protection from extreme heat is very impor-
tant). Run wires from the fireplace to that
location, use Thermostat Wire Table.
2) Connect the wires as per the wiring dia-
gram below.
FINAL CHECK
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly. This includes:
1) Clocking the appliance to ensure the cor-
rect firing rate (rate noted on label) at 15
minutes.
2) If required, adjusting the primary air to
ensure that the flame does not carbon. First
allow the unit to burn for 15 min. to stabilize.
3) Check for proper draft.
CAUTION
Any alteration to the product that causes
sooting or carboning that results in dam-
age to the exterior facia is not the respon-
sibility of the manufacturer.
CAUTION
Do not connect the
millivolt remote control wires
to the 120V wires.
3) Install 3 AAA alkaline batteries in transmitter
and 4 AA alkaline batteries in  the receiver.
Install the receiver and its cover in the wall.
Switch the  remote receiver to "remote"
mode. The remote control is now ready for
operation.
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
50 Ft.
32 Ft.
20 Ft.
12 Ft.
9 Ft.
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size                      Max. Length