Honeywell T8601D 사용자 설명서

다운로드
페이지 12
T8601D CHRONOTHERM® IV DELUXE PROGRAMMABLE THERMOSTATS
69-1410—2
2
Fig. 1. Typical location of thermostat.
Wallplate Installation
The thermostat can be mounted horizontally on the wall 
or on a 2 in. x 4 in. wiring box. Position wallplate 
horizontally on the wall or on a 2 in. x 4 in. wiring box.
1. Position and level the wallplate (for appearance 
only). The thermostat functions correctly even 
when not level. 
Fig. 2. Mounting the wallplate.
2. Use a pencil to mark the mounting holes. See 
Fig. 2.
3. Remove the wallplate from the wall and drill two 
3/16 in. holes in the wall (if drywall) as marked. For 
firmer material such as plaster, drill two 7/32 in. 
holes. Gently tap anchors (provided) into the drilled 
holes until flush with the wall.
4. Position the wallplate over the holes, pulling wires 
through the wiring opening.
5. Loosely insert the mounting screws into the holes.
6. Tighten mounting screws.
WIRING
All wiring must comply with local electrical codes and 
ordinances. Refer to Fig. 3 through 5 for typical hookups. 
A letter code is located near each terminal for 
identification.
CAUTION
Electrical Hazard. 
Can cause electric shock and equipment 
damage.
Disconnect power before beginning wiring.
1. Loosen the terminal screws on the wallplate and 
connect the system wires. See Fig. 6.
Fig. 3. Typical hookup in heat only application.
5 FEET
[1.5 METERS]
YES
NO
NO
NO
M10106
WIRES 
THROUGH WALL
WALL
MOUNTING 
HOLES
M15044
MOUNTING 
SCREWS
WALL
ANCHORS (2)
L1
(HOT)
L2
M10357
FAN
RELAY
G
C
THERMOSTAT
HEAT
RELAY
R
W
TRANSFORMER
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND 
OVERLOAD PROTECTION AS REQUIRED.
1
1