35 dpm toggle switch setting 
20 25 30 35 40
1
2
4
8 10
 
40 dpm toggle switch setting 
20 25 30 35 40
1
2
4
8 10
 
The OPEN and CLOSE LEDs indicate whether the needle valve is opening or closing. See items 5 
and 11 in Figure 6 on page 13. 
Pre-lube (pump off) Mode  
To select the Pre-lube mode, 24 V AC/DC must be applied to the S.B. terminals in the connection 
box (Figure 5). In this mode, the drip rate is automatically set to 2 dpm. 
Manual Control 
This mode permits emergency operation in the rare case when there is a suspected failure of the 
main circuitry. 
Select the manual mode by switching the Mode toggle switch to the upper MAN position (Figure 6). 
This mode bypasses the electronic control circuitry, and allows the operator to modify the drip rate 
by using the Open Valve (manual) and Close Valve (manual) push buttons. 
Use the Drip verification peephole (see Figure 7 below) to check the drip rate. 
In this mode, power is removed from the circuitry, except for the push buttons, motor, and Manual 
mode LED.