3100 Wood Stove Series (ACC)
A.  Hearth Protection Requirements
FLOOR PROTECTION:  Floor protector must be non-com-
bustible material, extending beneath heater and to the front, 
sides and rear as indicated.  The floor must be non-com-
bustible or otherwise adequately protected from radiant heat 
given off by the unit and from sparks and falling embers.  A 
layer of thin brick or ceramic tile over a combustible floor is 
not sufficient. 
For the Millennium Model In US installations, it is nec-
essary to install a floor protector of a minimum of /8 inch 
(9.5mm) thick metal clad millboard or equivalent a minimum 
of 16 inches (406mm) in front of glass  and 8 inches (20mm) 
to both sides of the fuel loading door.  Open the door and 
measure 8 inches  (20mm) from the side edge of the open-
ing in the face of the appliance. *
See exception. 
16 in. from glass
8 in.
Fuel loading door
4-7/8 in. 3-1/8 in.
1-5/8 in.
minimum
9-5/8 in.
minimum
Must extend 2 in. (51mm) beyond
each side of pipe (shaded area)
20mm (8 in.)
20mm
(8 in.)
20mm
(8 in.)
457mm (18 in.)
1260mm
(49-5/8 in.)
minimum
1041mm (41 in.)
minimum
In  Canada,  similar  floor  protection  must  be  provided  18 
inches (457mm) in front and 8 inches (20mm) from the 
sides and rear of the stove.  *
See exception.
*ExCEPTION:    Non-combustible  floor  protections  must 
extend beneath the flue pipe when installed with horizontal 
venting  and  extend  2  inches  (51mm)  beyond  each  side. 
See Figure 12.4.
USA required
Canada recommended
Figure 12.3
4
Installation
Figure 12.1
Figure 12.2
Figure 12.4
WARNING
Fire Risk.
•  Hearth pads must be installed exactly as 
specified.
High temperatures or hot embers may ignite 
concealed combustibles.
Millennium Model
1
-5/8
 in
.
27
-/8
 in
.
1-/4 in.
8
-15
/16
 in
.
-1
/16
 in
.
1
op
tio
na
l
co
ve
rag
e
51-1/16 in.
USA
USA
CANADA