DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-528
DIOD-DS1 (DS1 DIOD Trunk) 
9
Table 9-216.
TEST #314 DS1 CO Dial Tone Seizure Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be 
in use on a valid call. Use the status trunk command to determine when the 
port is available for testing.
1004
ABORT
The port has been seized by a user for a valid call. Use the status trunk 
command to determine when the port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1005
ABORT
Test failed due to incompatible configuration administered in trunk group 
form.
1. Look at the trunk group administration form and see if the trunk is 
incoming only, port 24 on a DS1 Interface with common control channel 
signaling, or an automatic CO type such as FX. Under any of these 
conditions this is a normal abort.
1018
ABORT
Test has been disabled via administration.
1. Verify that the ‘‘Maintenance Tests’’ field on the Trunk Group Form is set 
to ‘‘n.’’ To enable the test, issue the change trunk-group x command 
where ‘‘x’’ equals the number of the trunk group to be tested. Then 
change the entry in the ‘‘Maintenance Tests’’ field on the form to ‘‘y.’’
2. Repeat the test.
1020
ABORT
The DS1 Interface circuit pack is out-of-service.
1. Look for UDS1-BD errors in the Hardware Error Log. If present, refer to 
"UDS1-BD (UDS1 Interface Circuit Pack)" (DS1/UDS1 Trunk Circuit 
Pack).
2. Retry the command.
2000
ABORT
Response to the test request was not received within the allowable time 
period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Continued on next page