DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1055
MET-LINE (MET Line) 
9
MET Line Ringer Update Test (#62)
In this update, a ‘‘ringer on’’ or a ‘‘ringer off’’ message is sent to the firmware to 
start and stop the ringer on the set.
PASS
Hybrid Line Station Audits passed.
1. Although this test will never actually return a FAIL result except for the 
Internal system error described above, it is possible that it will enter Error 
Types 257 or 513 into the Error Log. To determine if there are any problems 
that don’t show up in the test result, look for these error types in the Error 
Log.
2. If these errors appear in the Error Log, or if user complaints persist, 
investigate by using other circuit pack tests, and by examining the station, 
wiring, and connections.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could be 
due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list config 
command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the busyout 
board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the linkage 
between the internal ID and the port. If this is not the case, check to ensure 
that there is a valid board inserted.
Table 9-418.
TEST #61 MET Line Station Audits Test  — Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page