The Auxiliary Contact can be operated at any time with the Push Button 21 (AUX. 
CONTACT). The LED 6 „Contact manual“ lights up as information that the Contact is 
manually operated, and LED 5 „Contact active“ lights up when the Contact is active. 
By pushing the Push Button 21 a second time, the Contact is disabled. By pushing it 
the third time, automatic functions are restored. 
5.5  Disabling some of the XP-COMPACT functions 
Each different function charger, inverter and transfer can be disabled. This is useful 
for specific applications witch required to disable some of these three functions. 
If you press the buttons 19 and 20 more than 2 seconds you can have access to the 
different possibilities, shown in the following diagram. 
In programming mode the display shows only the different types of program with the 
three LED’s 2, 7 and 9 to each function. To change the type of programming, press 
shortly the button 20 until you reach the right function used according to the table 
below. After 10 seconds the XP-COMPACT exits the programming mode and loads 
the new change. 
In user mode, the disabled functions are displayed by blinking LED. So you can see 
which mode is disabled. 
5.5.1  Diagram of the different modes 
Shows an off LED  
Shows a blinking LED 
Shows a lighted LED 
 
All the functions are enabled. This is the 
factory setting. 
 
The inverter is disabled. Only the transfer 
switch and the charger will work normal-
ly. 
 
Inverter and charger are both disabled. 
Only the transfer switch function is ena-
bled in input voltage and frequency is OK
 
Charger and transfer switch are disabled 
the inverter will work continuously even if 
there is a correct AC voltage at the input.