Operating Instructions and Parts Manual 
FP260200
www.chpower.com
Definition of terms 
(continued)
Motor Protection - If the unit is over 
worked, a thermal limiter will shut unit 
off. If this happens, switch unit to OFF, 
wait 30 minutes to cool, turn ON again 
to resume work.
Operation
lUbrIcatIOn
This is an oilless product and DOeS nOt 
require lubrication to operate.
beFOre FIrSt StartUP  
breaK-In PrOceDUre
Complete this procedure before using 
compressor for the first time. Once 
completed, it is not necessary to repeat.
1.   Turn regulator knob fully clockwise 
(to the right) to open air flow.
2.   Do not attach a hose or any other 
fitting to the compressor.
3.   Turn ON/OFF switch to OFF ( O 
position.
4.   Plug in power cord.
5.   Turn ON/OFF switch to ON ( I 
position. Allow compressor to run 
for 5 minutes.
6.   Turn ON/OFF switch to OFF ( O 
position.
7.   Unplug power cord.
OPeratInG PrOceDUre
1.   Turn switch to OFF ( O ) position and 
plug in power cord.
2.   Turn regulator knob 
counterclockwise to close air flow.
3.   Turn switch to ON ( I ) position.
4.   Compressor will build to maximum 
pressure and shut off.
5.   With hose attached to outlet of 
compressor, attach tire chuck or 
other tool to open end of hose.
6.   Adjust regulator to proper pressure 
for tool or tire. Operate tool per 
instructions.
As air is depleted from the tank by 
use of a tire chuck, tool, etc., the 
compressor will restart automatically 
at its preset “cut-in” pressure. When 
a tool is being used continuously, 
the compressor will cycle on and off 
automatically.
7.   Turn switch to OFF ( O ) position, 
unplug power cord and drain 
tank of air when finished using 
compressor.
User - Maintenance 
Instructions
 
 
 
Disconnect power source 
then release all pressure from 
the system before attempting 
to install, service, relocate or perform 
any maintenance. Service should be 
performed by an authorized service 
representative.
The compressor should be checked 
often for any visible problems and the 
following maintenance procedures 
should be performed each time the 
compressor is used.
aSMe SaFety valve
 
Do not  remove or  
  attempt to adjust 
the safety valve!
Check the safety valve by performing 
the following steps: 
1.   Plug the compressor in and run until 
shut off pressure is reached (see 
Operating Instructions).
2.   Wearing safety glasses, pull the 
ring on the safety valve to release 
pressure from compressor tank. Use 
your other hand to deflect fast-
moving air from being directed 
toward your face.
3.   The safety valve should close 
automatically at approximately 
40-50 psi. If the safety valve does 
not allow air to be released when 
you pull on the ring, or if it does 
not close automatically, it MUST be 
replaced.
DraIn tanK
With compressor shut off and pressure 
released, drain moisture from tank by 
opening drain valve underneath tank.
cleanInG
Turn power OFF and clean dust and dirt 
from pump cover, tank, and air lines.
IMPORTANT: Unit should be located as 
far from spraying area as hose will allow 
to prevent over-spray from clogging air 
filter.
enD OF OPeratIOn/StOraGe
1.   Turn ON / OFF switch to the OFF ( O 
position.
2.   Unplug power cord from wall outlet 
and wrap around handle area to 
prevent damage when not in use.
3.   Wearing safety glasses drain tank of 
air by pulling the ring on the safety 
valve. Use other hand to deflect 
fast moving air from being directed 
toward your face.
4.   Drain tank of condensation by 
opening drain valve on bottom of 
tank. Tank pressure should be below 
10 psi when draining tank.
5.   Air hose should be disconnected 
from compressor and hung open 
ends down to allow any moisture to 
drain.
6.   Compressor and hose should be 
stored in a cool, dry place.
Figure 6
Figure 5