ü  For MR2000U-2/3 
Changing the jumper status indicated on the control PCB inside die cast 
case determines parameters illustrated in the table below. (for MR2000U-JIS, 
only J3 is applicable) (for MR2000U-2, T3 is not applicable) 
 
 
 
 
 
JUMPER 
T1 
T2 
T3 
J1 
J2 
J3 
FUNCTION 
STATUS 
TRACK 1 
TRACK 2 
TRACK 3 
LEADING / 
STOP CODE 
RESERVED  CARD TYPE 
SHORT 
ENABLED 
ENABLED 
ENABLED 
DISABLED 
N.A. 
JIS II 
OPEN 
DISABLED  DISABLED  DISABLED 
ENABLED 
N.A. 
ISO 
DEFAULT 
SHORT 
SHORT 
SHORT 
OPEN 
OPEN 
OPEN 
Note 1: To use the USB interface MSR in operating system without USB 
support, please set USB keyboard enabled in BIOS (CMOS) setup. 
Note 2: Since this USB interface MSR works as a USB keyboard which is 
a normal HID (Human Interface Devices) in USB classification, no 
special driver shall be required. 
 
CN2 
U1 
 
U3 
CN1 
T1 
T2 
T3 
J1 
J2 
J3