Datalogic Scanning PD7100 사용자 설명서
Symbologies
154
PowerScan
®
PD7100 Corded
GS1 DataBar Expanded — cont.
GS1 DataBar Expanded Set Length 2
This feature specifies one of the barcode lengths for
GS1 DataBar Expanded Length
Control
. Length 2 is the maximum label length if in
Variable Length
Mode, or the sec-
ond fixed length if in
Fixed Length
Mode. Length includes the barcode’s data characters
only.
The length can be set from 1 to 74 characters. A setting of 0 specifies to ignore this length
(only one fixed length).
(only one fixed length).
Follow these instructions to set this feature:
1. Determine the desired character length (from 1 to 74). Pad the number with lead-
ing zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program-
ming Mode.
3. Scan the barcode: SELECT GS1 DATABAR EXPANDED LENGTH 2 SET-
TING.
4. Scan the appropriate two digits from the keypad in
Appendix E, Keypad
, that rep-
resent the length setting which was determined in the steps above. You will hear a
two-beep indication after the last character.
two-beep indication after the last character.
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
ming Mode.
This completes the procedure. See
Table 20
for some examples of how to set this feature.
Table 20. GS1 DataBar Expanded Length 2 Setting Examples
NOTE
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
abort and not save the entry string. You can then start again at the beginning.
STEP
ACTION
EXAMPLES
1
Desired Setting
00 (ignore second
length)
07 Characters
52 Characters
74 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT GS1 DATABAR EXPANDED LENGTH 2 SETTING
4
Scan Two Characters From
Appendix E, Keypad
‘0’ and ‘0’
‘0’ and ‘7’
‘5’ and ‘2’
‘7’ and ‘4’
5