Datalogic Scanning PD7100 사용자 설명서

다운로드
페이지 324
Symbologies
154
PowerScan
®
 PD7100 Corded
GS1 DataBar Expanded — cont.
GS1 DataBar Expanded Set Length 2
This feature specifies one of the barcode lengths for 
GS1 DataBar Expanded Length 
Control
. Length 2 is the maximum label length if in 
Variable Length
 Mode, or the sec-
ond fixed length if in 
Fixed Length
 Mode.  Length includes the barcode’s data characters 
only.
The length can be set from 1 to 74 characters. A setting of 0 specifies to ignore this length 
(only one fixed length).
Follow these instructions to set this feature:
1. Determine the desired character length (from 1 to 74). Pad the number with lead-
ing zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program-
ming Mode.
3. Scan the barcode: SELECT GS1 DATABAR EXPANDED LENGTH 2 SET-
TING.
4. Scan the appropriate two digits from the keypad in 
Appendix E, Keypad
, that rep-
resent the length setting which was determined in the steps above. You will hear a 
two-beep indication after the last character.
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
ming Mode.
This completes the procedure. See 
Table 20
 for some examples of how to set this feature.
Table 20. GS1 DataBar Expanded Length 2 Setting Examples
NOTE
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
STEP
ACTION
EXAMPLES
1
Desired Setting
00 (ignore second 
length)
07 Characters
52 Characters
74 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT GS1 DATABAR EXPANDED LENGTH 2 SETTING
4
Scan Two Characters From 
Appendix E, Keypad
 ‘0’ and ‘0’
‘0’ and ‘7’
‘5’ and ‘2’
 ‘7’ and ‘4’
5
Scan ENTER/EXIT PROGRAMMING MODE