Datalogic Scanning PD7100 사용자 설명서

다운로드
페이지 324
Code 39
Product Reference Guide
        
         169
Code 39 — cont.
Code 39 Set Length 2
This feature specifies one of the barcode lengths for 
Code 39 Length Control
. Length 2 
is the maximum label length if in 
Variable Length
 Mode, or the second fixed length if 
in
Fixed Length
 Mode. Length includes the barcode’s check, data, and full-ASCII shift 
characters.  The length does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length 
(only one fixed length).
Follow these instructions to set this feature:
1. Determine the desired character length (from 1 to 50 — or 0 to ignore this 
length). Pad the number with leading zeroes to yield two digits. For example: 0 = 
00, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program-
ming Mode.
3. Scan the barcode: SELECT CODE 39 LENGTH 2 SETTING.
4. Scan the appropriate two digits from the keypad in 
Appendix E, Keypad
, that rep-
resent the length setting which was determined in the steps above. You will hear a 
two-beep indication after the last character.
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
ming Mode.
This completes the procedure. See 
Table 22
 for some examples of how to set this feature.
Table 22. Code 39 Length 2 Setting Examples
NOTE
If you make a mistake, before the last character scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
STEP
ACTION
EXAMPLES
1
Desired Setting
00 (Ignore This 
Length)
07 Characters
15 Characters
50 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODE 39 LENGTH 2 SETTING
4
Scan Two Characters From 
Appendix E, Keypad
 ‘0’ and ‘0’
 ‘0’ and ‘7’
‘1’ and ‘5’
‘5’ AND ‘0’
5