Symbologies
254
PowerScan
®
 PD7100 Corded
Standard 2 of 5 — cont.
Standard 2 of 5 Set Length 1
This feature specifies one of the barcode lengths for 
Standard 2 of 5 Length Control
.
Length 1 is the minimum label length if in 
Variable Length
 Mode, or the first fixed 
length if in 
Fixed Length
 Mode. Length includes the barcode’s check and data charac-
ters.
The length can be set from 1 to 50 characters.
Follow these instructions to set this feature:
1. Determine the desired character length (from 1 to 50). Pad the number with lead-
ing zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program-
ming Mode.
3. Scan the barcode: SELECT STANDARD 2 OF 5 LENGTH 1 SETTING.
4. Scan the appropriate two digits from the keypad in 
Appendix E, Keypad
, that rep-
resent the length setting which was determined in the steps above. You will hear a 
two-beep indication after the last character.
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
ming Mode.
This completes the procedure. See 
Table 33
 for some examples of how to set this feature.
Table 33. Standard 2 of 5 Length 1 Setting Examples
NOTE
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
STEP
ACTION
EXAMPLES
1
Desired Setting
01 Character
07 Characters
15 Characters
50 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT STANDARD 2 OF 5 LENGTH 1 SETTING
4
Scan Two Characters From 
Appendix E, Keypad
 ‘0’ and ‘1’
 ‘0’ and ‘7’
 ‘1’ and ‘5’
‘5’ AND ‘0’