Datalogic Scanning PD7100 사용자 설명서

다운로드
페이지 324
RS-232/USB-Com Interfaces
70
PowerScan
®
 PD7100 Corded
Enable Character
Specifies the value of the RS-232 host command used to enable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected.
To set this feature:
Determine the desired character or value. 
A setting of 0xFF indicates the the Enable 
Character is not used (not available).
1. Determine the desired character or value.
2. Use the 
ASCII Chart
 on the inside back cover of this manual to find the hex equiv-
alent for the desired character/value.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program-
ming Mode.
4. Scan the barcode: SELECT ENABLE CHARACTER SETTING.
5. Scan the appropriate two alpha-numeric characters from the keypad in 
Appendix 
E, Keypad
, that represent the desired character/value in step 
2
 above. The second 
character will cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
ming Mode.
This completes the procedure. See 
Table 13
 for some examples of how to set this 
feature.
Table 13. Enable Character Setting Examples
NOTE
Setting to previously defined characters such as XON, XOFF, or host
commands conflicts with normal operation of these characters. 8-bit
data is not recognized when the option 
Data Bits
 has been set as 7
Data Bits.
STEP
ACTION
EXAMPLES
1
Desired character/value
‘e’
 ‘}’
‘E’
Enable Command 
Not Used
2
Hex equivalent
0x65
 0x7D
0x45
0xFF
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT DISABLE CHARACTER VALUE SETTING
5
Scan Two Characters From 
Appendix E, Keypad
‘6’ and ‘5’
‘7’ and ‘D’
‘4’ and ‘5’
‘F’ AND ‘F’
6