Datalogic Scanning QD2100 사용자 설명서

다운로드
페이지 320
RS-232/USB-Com Interfaces
56
QuickScan® QD2100
ACK NAK Timeout Value
This option specifies the amount of time the reader waits for an ACK character from the 
host following label transmission. The selectable timeout range is 200 milliseconds to 
15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout.
To set this value:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 200 (setting is in 200ms increments).  Pad the result with 
leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming 
Mode.
4. Scan the barcode: SELECT ACK NAK TIMEOUT VALUE SETTING.
5. Scan the appropriate two digits from the keypad in 
Appendix E, Keypad
, that represent 
the duration which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming 
Mode.
This completes the procedure. See 
Table 10
 for some examples of how to set this feature.
Table 10. ACK NAK Timeout Value Setting Examples
NOTE
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
STEP
ACTION
EXAMPLES
1
Desired Setting
200ms
1,000ms (1 sec.) 5200ms (5.2 sec.)
15,000ms (1 sec.)
2
Divide by 200
01
05
26
75
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT ACK NAK TIMEOUT VALUE SETTING
5
Scan Two Characters From 
Appendix E, Keypad
 ‘0’ and ‘1’
 ‘0’ and ‘5’
‘2’ and ‘6’
‘7’ and ‘5’
7