GE GFK-1918D 사용자 설명서
G E F a n u c P L C Ta r g e t s
Interacting with the PLC
GFK-1918D
CIMPLICITY Logic Developer - PLC Version 4.00
39
Data values at sequential addresses are displayed, by default, from right to left,
starting at the reference address specified. Both default and user-defined RVTs
display rows of 8 cells for discrete memory and rows of 10 cells for register
memory. The amount of data displayed in the columns depends on the data
display format.
starting at the reference address specified. Both default and user-defined RVTs
display rows of 8 cells for discrete memory and rows of 10 cells for register
memory. The amount of data displayed in the columns depends on the data
display format.
To cr eat e a us er- d efined Referen ce Vi ew Ta ble
• In the
Project tab of the
Navigator, right-click on the
Reference View Tables folder and choose New.
A new
Reference View Table with a default name is added to the folder.
Starting Address
Selected address
Format of selected address
Display format can be
selected for individual
cells or the entire
table.
selected for individual
cells or the entire
table.
This is the data at the
starting address.
starting address.
Subsequent addresses
are displayed right to
left by default.
are displayed right to
left by default.