Nortel Networks 311 사용자 설명서

다운로드
페이지 1134
Physical description
1055
To provide CEMUX communication with the card, changes are also required
to create an I/O entry for the card.
This card replaces the NTAK09 described in
The TMDI feature does not affect the NTAK09 functionality. The
configuration and maintenance changes to the card are not apparent to the
user. Call processing is not affected.
The NTRB21 card is installed only in the Media Gateway. It is not supported
in the Media Gateway Expansion. Up to four digital trunks are supported in
each Media Gateway. The NTRB21 card can be installed in slots 1, 2, 3,
and 4 of the Media Gateway.
ATTENTION
IMPORTANT!
Each Media Gateway that has a digital trunk must use a clock controller clocked
to an external reference clock.
Note: Clocking slips can occur between Media Gateways that are
clocked from different COs, if the COs are not synchronized. The slips
can degrade voice quality.
Contact your system supplier or your Nortel Networks representative to
verify that the NTRB21 digital trunk card is supported in your area.
Physical description
The NTRB21 card uses a standard 9.5" by 12.5" multi-layer printed
circuit board with buried power and ground layers.The clock controller
daughterboard is fastened by standoffs and connectors.
The NTRB21 card has seven faceplate LEDs. The first five LEDs are
associated with the NTRB21 card. The remaining two LEDs are associated
with the clock controller and DCHI daughterboards. See
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.