Nortel Networks 311 사용자 설명서
106
Option settings
S1 and S2—E33
Note: Possible jumper locations for vintage A (for different styles/series). These cards can only be
used in the option A setting:
used in the option A setting:
J3—H5 or E11
J4—H17 or E7
S1 and S2—E33
J4—H17 or E7
S1 and S2—E33
Note: Connectors and loop relations:
Even loop: J1 faceplate connector, jumper at J4 or S1
Odd loop: J2 faceplate connector, jumper at J3 or S2
Odd loop: J2 faceplate connector, jumper at J3 or S2
QPC441 3-Port Extender cards
For CS 1000M SG and MG systems, QPC441 vintage F or later must be
used in all modules.
used in all modules.
Table 44
QPC441 3PE card installed in the NT4N41CP PII Core Net modules
QPC441 3PE card installed in the NT4N41CP PII Core Net modules
Jumper Settings: Set Jumper RN27 at E35 to "A".
Switch Settings
Module
D20 switch position
NT4N41 CP Core/Net modules only
1
2
3
4
5
6
7
8
Group 0
off
on
on
off
on
on
on
on
Group 1
off
on
on
off
on
on
off
on
Group 2
off
on
on
off
on
off
on
on
Group 3
off
on
on
off
on
off
off
on
Group 4
off
on
on
off
off
on
on
on
Group 5
off
on
on
off
off
on
off
on
Group 6
off
on
on
off
off
off
on
on
Core/Net 0
(Shelf 0)
Group 7
off
on
on
off
off
off
off
on
Group 0
off
on
on
off
on
on
on
off
Group 1
off
on
on
off
on
on
off
off
Group 2
off
on
on
off
on
off
on
off
Group 3
off
on
on
off
on
off
off
off
Group 4
off
on
on
off
off
on
on
off
Group 5
off
on
on
off
off
on
off
off
Group 6
off
on
on
off
off
off
on
off
Core/Net 1
(Shelf 1)
Group 7
off
on
on
off
off
off
off
off
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.