QPC841 Quad Serial Data Interface card
SW14
Port 1
Port 2
Switch settings
SW15
Port 3
Port 4
1
2
3
4
5
6
7
8
14
15
off
off
off
off
off
off
off
off
Note 1: On SW16, positions 1, 2, 3, and 4 must be OFF.
Note 2: To avoid address conflicts, SW14 and SW15 can never use identical settings.
Note 3: To disable ports 1 and 2, set SW14 position 1 to ON. To disable ports 3 and 4, set SW15
position 1 to ON.
Baud rate switch settings
lists the switch
settings necessary to set the baud rate.
Table 454
QSDI card baud rate switch settings
Port 1 – SW10
Port 2 – SW11
Port 3 – SW12
Port 4 – SW13
Baud
rate
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
150
off
off
on
on
off
off
on
on
off
off
on
on
off
off
on
on
300
off
on
off
on
off
on
off
on
off
on
off
on
off
on
off
on
600
off
off
off
on
off
off
off
on
off
off
off
on
off
off
off
on
1200
off
on
on
off
off
on
on
off
off
on
on
off
off
on
on
off
2400
off
off
on
off
off
off
on
off
off
off
on
off
off
off
on
off
4800
off
on
off
off
off
on
off
off
off
on
off
off
off
on
off
off
9600
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
DTE/DCE mode switch settings
shows
the DTE/DCE mode selection switches for the four serial ports.
Table 455
QSDI card DTE/DCE mode switch settings
Port 1 – SW8
Port1 – SW9
Mode
1
2
3
4
5
6
1
2
3
4
5
6
DTE (Terminal)
on
on
on
on
on
on
off
off
off
off
off
off
DCE (Modem)
off
off
off
off
off
off
on
on
on
on
on
on
Port 2 – SW6
Port 2 – SW7
Mode
1
2
3
4
5
6
1
2
3
4
5
6
DTE (Terminal)
on
on
on
on
on
on
off
off
off
off
off
off
DCE (Modem)
off
off
off
off
off
off
on
on
on
on
on
on
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.